ProARTProCare Applications for Radiation Technology

Professional-grade QA testing suite for Linac, Diagnostic Radiology, and Nuclear Medicine.

Streamline your quality assurance workflow with automated analysis and comprehensive reporting.

Why ProART?

Built for medical physicists who demand precision and efficiency

Industry Standard

Quality assurance tests based on pylinac, trusted by medical physicists worldwide

Detailed Analytics

Comprehensive reports with pass/fail criteria and trends

Save Time

Automated analysis reduces manual calculation errors

Compliance Ready

Meet your requirements with documented results

Comprehensive Test Suite

Everything you need for radiation therapy quality assurance

Linac QA

5 subcategories

MLC/Jaws QA

3 tests
Picket Fence

Preview

Quantitative MLC positional accuracy analysis to evaluate leaf offsets, interdigitation accuracy, and dynamic delivery performance.

Run test
Field Analysis

Preview

Comprehensive 1D/2D beam profile evaluation including flatness, symmetry, penumbra, field size.

Run test
DRMLC

Preview

Dynamic MLC speed versus dose rate coupling verification.

Run test

Isocenter QA

3 tests
Starshot

Preview

Isocenter size determination via radiation spoke analysis to quantify gantry, collimator, or couch mechanical wobble.

Run test
Winston-Lutz

Preview

Sub-millimeter coincidence assessment of radiation and mechanical isocenters using BB-based EPID imaging.

Run test
Winston-Lutz Multi-Target

Preview

Multi-isocenter verification for SRS/SBRT workflows, enabling spatial accuracy assessment across multiple target coordinates.

Run test

CBCT and KV QA

10 tests
Leeds TOR

Preview

Planar kV image quality analysis of the Leeds TOR phantom for contrast-detail performance and spatial resolution assessment.

Run test
CatPhan 504

Preview

Comprehensive CBCT image quality evaluation including HU accuracy, uniformity, MTF, CNR, and geometric scaling.

Run test
CatPhan 503

Preview

Image quality assessment with CatPhan 503 focused on HU linearity, low-contrast detectability, and sensitometry.

Run test
CatPhan 600

Preview

Advanced CBCT QA with high-resolution MTF and low-contrast module analysis.

Run test
CatPhan 604

Preview

Extended image quality evaluation supporting enhanced low-contrast and geometric accuracy testing.

Run test
DoseLab MC2 KV

Preview

kV planar and CBCT image quality analysis using DoseLab MC2.

Run test
SNC KV

Preview

kV imaging QA for contrast, resolution, and uniformity.

Run test
SI QC KV

Preview

kV imaging quality control and constancy analysis.

Run test
Quart DVT

Preview

CT/CBCT image quality assessment with QUART DVT phantom.

Run test
TomoTherapy Cheese

Preview

Helical delivery dose verification using the TomoTherapy Cheese phantom.

Run test

VMAT QA

5 tests
DRGS

Preview

Dynamic VMAT gantry speed versus dose rate synchronization analysis.

Run test
DRMLC

Preview

Dynamic MLC speed versus dose rate coupling verification.

Run test
DRCS

Preview

Dynamic collimator speed versus dose rate coupling evaluation.

Run test
Dynalog File Analysis

Preview

Varian MLC log analysis for RMS error statistics and fluence reconstruction.

Run test
Trajectory Analysis

Preview

High-resolution trajectory log assessment of MLC, gantry, collimator, and couch.

Run test

MV Imaging QA

9 tests
Las Vegas

Preview

MV planar image quality assessment using Las Vegas phantom.

Run test
Elekta Las Vegas

Preview

MV image quality verification optimized for Elekta platforms.

Run test
PTW EPID

Preview

EPID-based dosimetric and image quality analysis.

Run test
DoseLab MC2 MV

Preview

MV planar image QA and dosimetric evaluation.

Run test
SNC MV

Preview

MV imaging QA for contrast, scaling, and detector uniformity.

Run test
SI QC -3

Preview

QC-3 phantom MV/kV imaging constancy verification.

Run test
IsoAlign

Preview

Alignment-focused planar QA for field size plus EPID and BB offset constancy using IsoAlign.

Run test
SNC FSQA

Preview

Special planar imaging QA for field size plus EPID and BB offset checks with the SNC FSQA phantom.

Run test
DoseLab RLF

Preview

Special planar imaging QA for field size plus EPID and BB offset checks with the DoseLab RLF phantom.

Run test

Diagnostic Radiology QA

5 subcategories

2D KV Imaging

6 tests
Leeds TOR

Preview

Planar kV image quality analysis of the Leeds TOR phantom for contrast-detail performance and spatial resolution assessment.

Run test
DoseLab MC2 KV

Preview

kV planar and CBCT image quality analysis using DoseLab MC2.

Run test
SNC KV

Preview

kV imaging QA for contrast, resolution, and uniformity.

Run test
SI QC KV

Preview

kV imaging quality control and constancy analysis.

Run test
FC2

Preview

Field size, EPID offset, and BB offset verification using the Standard Imaging FC2 phantom.

Run test
IMTL Rad

Preview

Planar QA verification of field size plus EPID and BB offsets using the IMTL Rad phantom.

Run test

Ultrasound QA

2 tests
Ultrasound Linear

Preview

Linear-probe ultrasound QA with mode verification, low-value distribution analysis, coefficient of variation, and skew tracking.

Run test
Ultrasound Curved

Preview

Curved-probe ultrasound QA with mode verification, low-value distribution analysis, coefficient of variation, and skew tracking.

Run test

Computed Tomography QA

7 tests
CatPhan 504

Preview

Comprehensive CBCT image quality evaluation including HU accuracy, uniformity, MTF, CNR, and geometric scaling.

Run test
CatPhan 503

Preview

Image quality assessment with CatPhan 503 focused on HU linearity, low-contrast detectability, and sensitometry.

Run test
CatPhan 600

Preview

Advanced CBCT QA with high-resolution MTF and low-contrast module analysis.

Run test
CatPhan 604

Preview

Extended image quality evaluation supporting enhanced low-contrast and geometric accuracy testing.

Run test
ACR CT

Preview

ACR CT accreditation phantom image quality evaluation.

Run test
GE Helios CT Daily QA

Preview

Daily CT phantom QA for GE Helios with contrast, MTF, low-contrast, noise, and uniformity analysis.

Run test
Quart DVT

Preview

CT/CBCT image quality assessment with QUART DVT phantom.

Run test

ACR Mammography QA

2 tests
ACR FFDM Mammo

Preview

Digital mammography QA using ACR FFDM phantom.

Run test
Small ACR Mammo

Preview

Digital mammography QA using the Small ACR phantom.

Run test

ACR MRI QA

1 tests
ACR MRI Phantom

Preview

MRI system QA including geometric distortion, uniformity, and SNR.

Run test

Nuclear Medicine QA

2 subcategories

SPECT QA

9 tests
Max Count Rate

Preview

Detector count-rate linearity and saturation threshold evaluation.

Run test
Planar Uniformity

Preview

Flood-field detector uniformity analysis.

Run test
Center of Rotation

Preview

Mechanical and reconstruction isocenter alignment verification.

Run test
Tomographic Resolution

Preview

3D spatial resolution quantification in reconstructed datasets.

Run test
Sensitivity

Preview

System detection efficiency evaluation.

Run test
Four Bar Resolution

Preview

High-contrast spatial resolution using bar-pattern analysis.

Run test
Four Quadrant Resolution

Preview

Quadrant-based resolution uniformity evaluation.

Run test
Tomographic Uniformity

Preview

Volumetric uniformity assessment across reconstructed slices.

Run test
Tomographic Contrast

Preview

Low-contrast detectability analysis using CNR metrics.

Run test

PET/CT QA

1 tests
PET/CT WB NEMA IQ

Preview

Whole-body PET/CT image quality and quantitative performance per NEMA IQ standards.

Run test